NSN: 6115-01-547-8552 (POWER PLANT, UTILITY, PU-824A/T) - ArmyProperty.com

NSN 6115-01-547-8552:

POWER PLANT, UTILITY, PU-824A/T
(NSN 6115015478552 / NIIN 015478552)

Procurement:





Invalid emails will appear to work, but in reality we will NOT receive them. Please make sure you type it correctly.

User Details

Order Details


*Required fields

Accountability:



$250,000.00






Manufacturers / Distributors / Merchants :




Related Products

6115-01-547-8513
POWER PLANT, UTILITY, PU-823T
6115-01-547-6738
POWER PLANT, UTILITY, PU-822A/T
6115-01-547-6713
POWER PLANT, UTILITY, PU-821/T
6115-01-547-2420
GENERATOR SET,GASOL
6115-01-547-8569
STATOR,GENERATOR
6115-01-547-9660
ROTOR ASSEMBLY
6115-01-548-1866
ROTOR ASSEMBLY
6115-01-548-1867
ROTOR ASSEMBLY

FLIS/Fedlog Information

I) Identification

FIIG A23900
INC 62040 — POWER PLANT,UTILITY
CRIT CD X — THE ITEM DOES NOT HAVE A NUCLEAR HARDENED FEATURE OR ANY OTHER CRITICAL FEATURE SUCH AS TOLERANCE, FIT RESTRICTION OR APPLICATION.
II 4 — PARTIAL DESCRIPTIVE ITEM IDENTIFICATION (TYPE 1 CONCEPT)
RPD MRC 2 — THE APPROVED ITEM NAME APPLIED TO THIS ITEM EXISTS FOR USE EXCLUSIVELY WITH THE PARTIAL DESCRIPTIVE METHOD OF ITEM IDENTIFICATION -MISCELLANEOUS ITEMS FEDERAL ITEM IDENTIFICATION GUIDE A239.
DMIL B — USML ITEMS - MUTILATION TO THE POINT OF SCRAP REQUIRED WORLDWIDE. (NOTE 7).
DMIL INT CD ---
NIIN ASGMT 2007032 (February 01, 2007)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI A — NO KNOWN ELECTROSTATIC DISCHARGE (ESD) OR ELECTROMAGNETIC INTERFERENCE (EMI) SENSITIVITY.
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 3 — DESIGN CONTROL REFERENCE. THE PRIMARY NUMBER USED TO IDENTIFY AN ITEM OF PRODUCT... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... ZZ --- --- --- --- --- ---
x x --- 3 — DESIGN CONTROL REFERENCE. THE PRIMARY NUMBER USED TO IDENTIFY AN ITEM OF PRODUCT... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... ZZ --- --- --- --- --- ---
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... ZZ --- --- --- --- --- ---

III) Management

EFF DT 2007032
MOE DA — DEPARTMENT OF THE ARMY
AAC A — SERVICE/AGENCY-REGULATED (SERVICE/AGENCY USE ONLY.) ISSUE, TRANSFER, OR SHIPMENT IS CONTROLLED BY AUTHORITIES ABOVE THE ICP LEVEL TO ASSURE PROPER AND EQUITABLE DISTRIBUTION. 1. THE USE OR STOCKAGE OF THE ITEM REQUIRES RELEASE AUTHORITY BAS...
SOS B16 — US ARMY COMMUNICATIONS-ELECTRONICS COMMAND AND FORT MONMOUTH FORT MONMOUTH, NJ 07703-5016
UI EA — A NUMERIC QUANTITY OF ONE ITEM OF SUPPLY. DO NOT USE IF A MORE SPECIFIC TERM APPLIES, SUCH AS KIT, SET, ASSORTMENT, ASSEMBLY, GROUP, SHEET, PLATE, STRIP, OR LENGTH.
UI PRICE $250,000.00
QUP 1 — 1
CIIC U — UNCLASSIFIED
SLC 0 — NON-DETERIORATIVE
REP D
USC L — LEAD SERVICE - 22 (REPAIRABLE)