NSN: 5995-01-513-7367 (CABLE ASSEMBLY, SPECIAL-PURPOSE) - ArmyProperty.com

NSN 5995-01-513-7367:

CABLE ASSEMBLY, SPECIAL-PURPOSE
(NSN 5995015137367 / NIIN 015137367)

Procurement:





Invalid emails will appear to work, but in reality we will NOT receive them. Please make sure you type it correctly.

User Details

Order Details


*Required fields

Accountability:



------




Manufacturers / Distributors / Merchants :




Related Products

5995-01-513-7364
CABLE ASSEMBLY, SPECIAL-PURPOSE
5995-01-513-7363
CABLE ASSEMBLY, POWER
5995-01-513-7082
CABLE ASSEMBLY, SPECIAL-PURPOSE
5995-01-513-7077
CABLE ASSEMBLY, SPECIAL-PURPOSE
5995-01-513-7663
CABLE ASSEMBLY, POWER
5995-01-513-7679
CABLE ASSEMBLY, POWER
5995-01-513-7825
CABLE ASSEMBLY, SPECIAL-PURPOSE
5995-01-513-7826
CABLE ASSEMBLY, SPECIAL-PURPOSE

FLIS/Fedlog Information

I) Identification

FIIG A077A0
INC 00782 — CABLE ASSEMBLY,SPEC
CRIT CD X — THE ITEM DOES NOT HAVE A NUCLEAR HARDENED FEATURE OR ANY OTHER CRITICAL FEATURE SUCH AS TOLERANCE, FIT RESTRICTION OR APPLICATION.
II 4 — PARTIAL DESCRIPTIVE ITEM IDENTIFICATION (TYPE 1 CONCEPT)
RPD MRC 5 — AN APPROVED ITEM NAME AND FIIG MAY EXIST BUT LACK OF TECHNICAL DATA AND/OR THE PRESS OF TIME FORCE TEMPORARY USE OF THE PARTIAL DESCRIPTIVE OR REFERENCE METHOD.
DMIL B — USML ITEMS - MUTILATION TO THE POINT OF SCRAP REQUIRED WORLDWIDE. (NOTE 7).
DMIL INT CD ---
NIIN ASGMT 2003276 (October 03, 2003)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI A — NO KNOWN ELECTROSTATIC DISCHARGE (ESD) OR ELECTROMAGNETIC INTERFERENCE (EMI) SENSITIVITY.
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 3 — DESIGN CONTROL REFERENCE. THE PRIMARY NUMBER USED TO IDENTIFY AN ITEM OF PRODUCT... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 1 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING AND THE DRAWING WAS AVAILABLE T... ZZ --- --- --- --- --- ---

III) Management

EFF DT 2012275
MOE DF — DEPARTMENT OF THE AIR FORCE
AAC C — SERVICE/AGENCY-MANAGED (SERVICE/AGENCY USE ONLY.) ISSUE, TRANSFER, OR SHIPMENT IS NOT SUBJECT TO SPECIALIZED CONTROLS OTHER THAN THOSE IMPOSED BY INDIVIDUAL SERVICES SUPPLY POLICY. 1. THE ITEM IS CENTRALLY MANAGED, STOCKED, AND ISSUED. 2. R...
SOS FLZ — WARNER ROBINS AIR LOGISTICS CENTER ROBINS AFB , GEORGIA 31098-5609
UI EA — A NUMERIC QUANTITY OF ONE ITEM OF SUPPLY. DO NOT USE IF A MORE SPECIFIC TERM APPLIES, SUCH AS KIT, SET, ASSORTMENT, ASSEMBLY, GROUP, SHEET, PLATE, STRIP, OR LENGTH.
UI PRICE x
QUP 1 — 1
CIIC U — UNCLASSIFIED
SLC 0 — NON-DETERIORATIVE
REP T
USC L — LEAD SERVICE - 22 (REPAIRABLE)