NSN: 5995-01-070-4098 (CABLE ASSEMBLY, SPECIAL-PURPOSE) - ArmyProperty.com

NSN 5995-01-070-4098:

CABLE ASSEMBLY, SPECIAL-PURPOSE
(NSN 5995010704098 / NIIN 010704098)

Procurement:





Invalid emails will appear to work, but in reality we will NOT receive them. Please make sure you type it correctly.

User Details

Order Details


*Required fields

Accountability:



------




Manufacturers / Distributors / Merchants :




Related Products

5995-01-070-3990
LEAD,ELECTRICAL
5995-01-070-3939
CABLE ASSEMBLY,RADI
5995-01-070-3938
CABLE ASSEMBLY,RADI
5995-01-070-3937
CABLE ASSEMBLY,RADI
5995-01-070-4284
CABLE ASSEMBLY, POWER
5995-01-070-4285
CABLE ASSEMBLY,RADI
5995-01-070-4286
LEAD,ELECTRICAL
5995-01-070-4409
LEAD,ELECTRICAL

FLIS/Fedlog Information

I) Identification

FIIG A077A0
INC 00782 — CABLE ASSEMBLY,SPEC
CRIT CD N — THE ITEM DOES NOT HAVE A CRITICAL FEATURE SUCH AS TOLERANCE, FIT RESTRICTIONS OR APPLICATION. NUCLEAR HARDNESS PROPERTIES HAVE NOT BEEN DETERMINED (NOT VALID FOR INPUT).
II M — PARTIAL DESCRIPTIVE - REFERENCE ITEM IDENTIFICATION (TYPE 1A CONCEPT)
RPD MRC 3 — AN APPROVED ITEM NAME AND FIIG EXIST BUT THE ITEM INVOLVED IS SO UNIQUE IN DESIGN THAT IT CANNOT BE FULLY DESCRIBED IN ACCORDANCE WITH THE FIIG.
DMIL B — USML ITEMS - MUTILATION TO THE POINT OF SCRAP REQUIRED WORLDWIDE. (NOTE 7).
DMIL INT CD ---
NIIN ASGMT 1979011 (January 11, 1979)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI A — NO KNOWN ELECTROSTATIC DISCHARGE (ESD) OR ELECTROMAGNETIC INTERFERENCE (EMI) SENSITIVITY.
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 3 — DESIGN CONTROL REFERENCE. THE PRIMARY NUMBER USED TO IDENTIFY AN ITEM OF PRODUCT... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... ZZ --- --- --- --- --- ---
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 9 — A REFERENCE NUMBER WHICH WAS THE DESIGN CONTROL REFERENCE FOR THE ITEM OF SUPPLY... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... CL 1 — NUMBER IS FORMATTED AS CONFIGURED ON THE ORIGINATING DOCUMENT WITH THE EXCEPTION... A — MANUFACTURER AND REFERENCE NUMBER ARE AUTHORIZED FOR PROCUREMENT. UNDER THIS REF... --- --- --- ---

III) Management

EFF DT 2012275
MOE DA — DEPARTMENT OF THE ARMY
AAC X — SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A POTENTIALLY INACTIVE NSN WHICH MUST BE RETAINED IN THE SUPPLY SYSTEM AS AN ITEM OF SUPPLY BECAUSE (1) STOCKS OF THE ITEM ARE ON HAND OR IN USE BELOW THE WHOLESALE LEVEL AND (2) THE NSN IS...
SOS B16 — US ARMY COMMUNICATIONS-ELECTRONICS COMMAND AND FORT MONMOUTH FORT MONMOUTH, NJ 07703-5016
UI EA — A NUMERIC QUANTITY OF ONE ITEM OF SUPPLY. DO NOT USE IF A MORE SPECIFIC TERM APPLIES, SUCH AS KIT, SET, ASSORTMENT, ASSEMBLY, GROUP, SHEET, PLATE, STRIP, OR LENGTH.
UI PRICE x
QUP 1 — 1
CIIC U — UNCLASSIFIED
SLC 0 — NON-DETERIORATIVE
REP D
USC L — LEAD SERVICE - 22 (REPAIRABLE)