NSN: 5945-01-293-3540 (RELAY ASSEMBLY) - ArmyProperty.com

NSN 5945-01-293-3540:

RELAY ASSEMBLY
(NSN 5945012933540 / NIIN 012933540)

Procurement:





Invalid emails will appear to work, but in reality we will NOT receive them. Please make sure you type it correctly.

User Details

Order Details


*Required fields

Accountability:



------




Manufacturers / Distributors / Merchants :




Related Products

5945-01-293-3309
RELAY ASSEMBLY
5945-01-293-2783
RELAY ASSEMBLY
5945-01-293-2561
CONTACT SET,RELAY
5945-01-293-2472
RELAY,HYBRID
5945-01-293-3848
SOLENOID,ELECTRICAL
5945-01-293-3852
RELAY ASSEMBLY
5945-01-293-3889
RELAY,ELECTROMAGNET
5945-01-293-3890
RELAY,ELECTROMAGNET

FLIS/Fedlog Information

I) Identification

FIIG T142-B
INC 00447 — RELAY ASSEMBLY
CRIT CD X — THE ITEM DOES NOT HAVE A NUCLEAR HARDENED FEATURE OR ANY OTHER CRITICAL FEATURE SUCH AS TOLERANCE, FIT RESTRICTION OR APPLICATION.
II 4 — PARTIAL DESCRIPTIVE ITEM IDENTIFICATION (TYPE 1 CONCEPT)
RPD MRC 3 — AN APPROVED ITEM NAME AND FIIG EXIST BUT THE ITEM INVOLVED IS SO UNIQUE IN DESIGN THAT IT CANNOT BE FULLY DESCRIBED IN ACCORDANCE WITH THE FIIG.
DMIL D — USML ITEMS - DEMIL REQUIRED. DESTROY ITEM AND COMPONENTS TO PREVENT RESTORATION OR REPAIR TO A USABLE CONDITION. (NOTE 5).
DMIL INT CD ---
NIIN ASGMT 1989032 (February 01, 1989)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI A — NO KNOWN ELECTROSTATIC DISCHARGE (ESD) OR ELECTROMAGNETIC INTERFERENCE (EMI) SENSITIVITY.
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 3 — DESIGN CONTROL REFERENCE. THE PRIMARY NUMBER USED TO IDENTIFY AN ITEM OF PRODUCT... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... CL --- --- --- --- --- ---

III) Management

EFF DT 2012275
MOE DA — DEPARTMENT OF THE ARMY
AAC X — SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A POTENTIALLY INACTIVE NSN WHICH MUST BE RETAINED IN THE SUPPLY SYSTEM AS AN ITEM OF SUPPLY BECAUSE (1) STOCKS OF THE ITEM ARE ON HAND OR IN USE BELOW THE WHOLESALE LEVEL AND (2) THE NSN IS...
SOS B16 — US ARMY COMMUNICATIONS-ELECTRONICS COMMAND AND FORT MONMOUTH FORT MONMOUTH, NJ 07703-5016
UI EA — A NUMERIC QUANTITY OF ONE ITEM OF SUPPLY. DO NOT USE IF A MORE SPECIFIC TERM APPLIES, SUCH AS KIT, SET, ASSORTMENT, ASSEMBLY, GROUP, SHEET, PLATE, STRIP, OR LENGTH.
UI PRICE x
QUP 1 — 1
CIIC 7 — CLASSIFIED: ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WIT...
SLC 0 — NON-DETERIORATIVE
REP D
USC L — LEAD SERVICE - 22 (REPAIRABLE)