I) Identification

FIIG A32200
INC 42816 — SWITCH,ELECTRONIC
CRIT CD X — THE ITEM DOES NOT HAVE A NUCLEAR HARDENED FEATURE OR ANY OTHER CRITICAL FEATURE SUCH AS TOLERANCE, FIT RESTRICTION OR APPLICATION.
II 4 — PARTIAL DESCRIPTIVE ITEM IDENTIFICATION (TYPE 1 CONCEPT)
RPD MRC 5 — AN APPROVED ITEM NAME AND FIIG MAY EXIST BUT LACK OF TECHNICAL DATA AND/OR THE PRESS OF TIME FORCE TEMPORARY USE OF THE PARTIAL DESCRIPTIVE OR REFERENCE METHOD.
DMIL B — USML ITEMS - MUTILATION TO THE POINT OF SCRAP REQUIRED WORLDWIDE. (NOTE 7).
DMIL INT CD ---
NIIN ASGMT 2008205 (July 24, 2008)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI A — NO KNOWN ELECTROSTATIC DISCHARGE (ESD) OR ELECTROMAGNETIC INTERFERENCE (EMI) SENSITIVITY.
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 9 — A REFERENCE NUMBER WHICH WAS THE DESIGN CONTROL REFERENCE FOR THE ITEM OF SUPPLY... 1 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING AND THE DRAWING WAS AVAILABLE T... ZZ --- B — MANUFACTURER AND/OR REFERENCE NUMBER ARE NOT AUTHORIZED FOR PROCUREMENT. (NOTE: ... --- --- --- ---

III) Management

EFF DT 2012275
MOE DA — DEPARTMENT OF THE ARMY
AAC C — SERVICE/AGENCY-MANAGED (SERVICE/AGENCY USE ONLY.) ISSUE, TRANSFER, OR SHIPMENT IS NOT SUBJECT TO SPECIALIZED CONTROLS OTHER THAN THOSE IMPOSED BY INDIVIDUAL SERVICES SUPPLY POLICY. 1. THE ITEM IS CENTRALLY MANAGED, STOCKED, AND ISSUED. 2. R...
SOS B16 — US ARMY COMMUNICATIONS-ELECTRONICS COMMAND AND FORT MONMOUTH FORT MONMOUTH, NJ 07703-5016
UI EA — A NUMERIC QUANTITY OF ONE ITEM OF SUPPLY. DO NOT USE IF A MORE SPECIFIC TERM APPLIES, SUCH AS KIT, SET, ASSORTMENT, ASSEMBLY, GROUP, SHEET, PLATE, STRIP, OR LENGTH.
UI PRICE x
QUP 1 — 1
CIIC U — UNCLASSIFIED
SLC 0 — NON-DETERIORATIVE
REP D
USC L — LEAD SERVICE - 22 (REPAIRABLE)