NSN: 4710-01-016-6331 (TUBE,METALLIC) - ArmyProperty.com

NSN 4710-01-016-6331:

TUBE,METALLIC
(NSN 4710010166331 / NIIN 010166331)

Procurement:





Invalid emails will appear to work, but in reality we will NOT receive them. Please make sure you type it correctly.

User Details

Order Details


*Required fields

Accountability:



------




Manufacturers / Distributors / Merchants :




Related Products

4710-01-016-6328
TUBE,METALLIC
4710-01-016-6327
TUBE,METALLIC
4710-01-016-6326
TUBE,METALLIC
4710-01-016-6325
TUBE,METALLIC
4710-01-016-6555
SOLDER ACCESS FITTI
4710-01-016-7384
TUBE,BENT,METALLIC
4710-01-016-7403
TUBE,METALLIC

FLIS/Fedlog Information

I) Identification

FIIG A004A0
INC 31979 — TUBE,METALLIC
CRIT CD Y — THE ITEM DOES NOT HAVE A NUCLEAR HARDENED FEATURE BUT DOES HAVE OTHER CRITICAL FEATURE(S) SUCH AS TOLERANCE, FIT RESTRICTIONS OR APPLICATION.
II 4 — PARTIAL DESCRIPTIVE ITEM IDENTIFICATION (TYPE 1 CONCEPT)
RPD MRC 3 — AN APPROVED ITEM NAME AND FIIG EXIST BUT THE ITEM INVOLVED IS SO UNIQUE IN DESIGN THAT IT CANNOT BE FULLY DESCRIBED IN ACCORDANCE WITH THE FIIG.
DMIL F — USML ITEMS - DEMIL REQUIRED. ITEM/TECHNICAL MANAGERS OR EQUIPMENT/PRODUCT SPECIALISTS WILL FURNISH SPECIAL DEMIL INSTRUCTIONS. (NOTE 3).
DMIL INT CD ---
NIIN ASGMT 1976046 (February 15, 1976)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI ---
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 1 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT DOES NOT IDENTIFY AN I... C — THE REFERENCE NUMBER IS REPRESENTED BY AN ENGINEERING DRAWING. THE DRAWING IS AV... HX --- --- --- --- --- ---
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 1 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT DOES NOT IDENTIFY AN I... C — THE REFERENCE NUMBER IS REPRESENTED BY AN ENGINEERING DRAWING. THE DRAWING IS AV... HX --- --- --- --- --- ---
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 1 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT DOES NOT IDENTIFY AN I... 3 — THE REFERENCE NUMBER IS REPRESENTED BY TECHNICAL DOCUMENTATION OTHER THAN A DRAW... HX --- --- --- --- --- ---
x x --- 5 — SECONDARY REFERENCE. ANY ADDITIONAL NUMBER, OTHER THAN A PRIMARY NUMBER (CODES 1... 1 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT DOES NOT IDENTIFY AN I... 3 — THE REFERENCE NUMBER IS REPRESENTED BY TECHNICAL DOCUMENTATION OTHER THAN A DRAW... HX --- --- --- --- --- ---

III) Management

EFF DT 2012275
MOE DN — DEPARTMENT OF THE NAVY
AAC D — DOD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED ISSUE, TRANSFER, OR SHIPMENT IS NOT SUBJECT TO SPECIALIZED CONTROLS OTHER THAN THOSE IMPOSED BY THE INTEGRATED MATERIEL MANAGER/SERVICE SUPPLY POLICY. 1. THE ITEM IS CENTRALLY MANAGED, ST...
SOS NRP — NAVICP-ERP 700 ROBBINS AVENUE PHILADELPHIA, PA 19111-5098
UI IN — UNIT OF LINEAR MEASUREMENT, EQUIVALENT TO 1/12 OF A FOOT AND SOMETIMES EXPRESSED AS LINEAR INCH.
UI PRICE x
QUP Z — * SPECIAL REQUIREMENTS.
CIIC 7 — CLASSIFIED: ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WIT...
SLC 0 — NON-DETERIORATIVE
REP M
USC N — U.S. NAVY