NSN: 1015-01-522-2630 (TUBE,CANNON) - ArmyProperty.com

NSN 1015-01-522-2630:

TUBE,CANNON
(NSN 1015015222630 / NIIN 015222630)

Procurement:





Invalid emails will appear to work, but in reality we will NOT receive them. Please make sure you type it correctly.

User Details

Order Details


*Required fields

Accountability:



------




Manufacturers / Distributors / Merchants :




Related Products

1015-01-522-0775
PIN,FIRING
1015-01-521-8201
BIPOD ASSEMBLY,MORT
1015-01-521-7953
CYLINDER ASSEMBLY,E
1015-01-521-6926
ELEVATION MECHANISM
1015-01-522-3440
CAP,BREECH
1015-01-523-7307
laser AN/PSQ-18 M203 day/night sight
1015-01-524-0125
MODIFICATION KIT,GU
1015-01-524-3275
CYLINDER,EQUILIBRAT

FLIS/Fedlog Information

I) Identification

FIIG T102-G
INC 21725 — TUBE,CANNON
CRIT CD X — THE ITEM DOES NOT HAVE A NUCLEAR HARDENED FEATURE OR ANY OTHER CRITICAL FEATURE SUCH AS TOLERANCE, FIT RESTRICTION OR APPLICATION.
II 4 — PARTIAL DESCRIPTIVE ITEM IDENTIFICATION (TYPE 1 CONCEPT)
RPD MRC 3 — AN APPROVED ITEM NAME AND FIIG EXIST BUT THE ITEM INVOLVED IS SO UNIQUE IN DESIGN THAT IT CANNOT BE FULLY DESCRIBED IN ACCORDANCE WITH THE FIIG.
DMIL D — USML ITEMS - DEMIL REQUIRED. DESTROY ITEM AND COMPONENTS TO PREVENT RESTORATION OR REPAIR TO A USABLE CONDITION. (NOTE 5).
DMIL INT CD ---
NIIN ASGMT 2004205 (July 24, 2004)
PMIC A — ITEM DOES NOT CONTAIN PRECIOUS METAL.
ADP 0 — REPRESENTS ITEMS WITH NO ADP COMPONENTS
ESD EMI A — NO KNOWN ELECTROSTATIC DISCHARGE (ESD) OR ELECTROMAGNETIC INTERFERENCE (EMI) SENSITIVITY.
HMIC N — INDICATES THERE IS NO DATA IN THE HMIRS AND THE NSN IS IN A FSC NOT GENERALLY SUSPECTED OF CONTAINING HAZARDOUS MATERIALS.
HCC ---

II) Reference/Part Number

REF PN
CAGE CD
STAT
RNCC
RNVC
DAC
RNAAC
RNFC
RNSC
RNJC
SADC
HCC
MSDS
x x --- 3 — DESIGN CONTROL REFERENCE. THE PRIMARY NUMBER USED TO IDENTIFY AN ITEM OF PRODUCT... 2 — A DESIGN CONTROL REFERENCE OR OTHER REFERENCE NUMBER THAT IS AN ITEM-IDENTIFYING... 5 — THE REFERENCE NUMBER IS REPRESENTED BY A DRAWING, BUT THE DRAWING WAS NOT AVAILA... ZZ --- --- --- --- --- ---

III) Management

EFF DT 2012275
MOE DA — DEPARTMENT OF THE ARMY
AAC B — INVENTORY CONTROL POINT (ICP)-REGULATED (SERVICE/AGENCY USE ONLY.) ISSUE, TRANSFER, OR SHIPMENT IS CONTROLLED BY THE ICP. 1. THE USE OR STOCKAGE OF THE ITEM REQUIRES RELEASE AUTHORITY BASED ON PRIOR OR CONCURRENT JUSTIFICATION. 2. REQUISITI...
SOS B14 — U.S. ARMY ARMAMENT AND CHEMICAL ACQUISITION AND LOGISTICS ACTIVITY, ATTN: AMSTA-AC, ROCK ISLAND,IL 61299-6000
UI EA — A NUMERIC QUANTITY OF ONE ITEM OF SUPPLY. DO NOT USE IF A MORE SPECIFIC TERM APPLIES, SUCH AS KIT, SET, ASSORTMENT, ASSEMBLY, GROUP, SHEET, PLATE, STRIP, OR LENGTH.
UI PRICE x
QUP 1 — 1
CIIC N — FIREARMS PIECE PARTS AND NONLETHAL FIREARMS
SLC 0 — NON-DETERIORATIVE
REP D
USC L — LEAD SERVICE - 22 (REPAIRABLE)